期刊文献+

大破口LOCA喷放模拟实验启动方法研究

Investigations on Startup Methods of Large LOCA Blowdown Simulation Experiments
原文传递
导出
摘要 地坑滤网性能评价及下游效应分析中通常需要开展大破口失水事故(LOCA)喷放模拟实验。本研究采用双膜爆破片结合气动阀实现大破口LOCA喷放模拟实验启动压力的精确控制和高能流体的瞬间释放。压力测量结果表明:双膜放气启动压力损失最大,单膜启动压力爬升较慢,双膜充气启动在压力损失、压力爬升速度和压力精度上都能准确模拟大破口LOCA喷放物理过程。最后采用双膜充气启动方法对双壁盒式保温结构进行射流破坏试验,结果表明本装置提供的冲击力度足够。 The large LOCA blowdown simulation experiment is usually needed for the purpose of the performance evaluation of containment sump strainer and downstream effect analysis. In this paper, large LOCA blowdown simulation experiment was conducted by double rupture discs combining with a pneumatic valve, and the accurate controlling of starting pressure and the instantaneous release of high-energy fluid was realized. The measurement results of dynamic pressure indicate that the pressure lose of double discs bleed starting mode is the largest, and the total pressure rise velocity is relative slow for the single disc starting mode. Double discs charging starting mode can accurately simulate large LOCA blowdown physical process in term of pressure loss, pressure rise velocity and pressure accuracy. Finally, jet impinging destruction tests for double-wall encapsulated insulation configuration were carried out by double discs charging starting mode. The results indicate that the impact load supplied by the present facility is sufficient.
出处 《核动力工程》 EI CAS CSCD 北大核心 2016年第S2期146-149,共4页 Nuclear Power Engineering
关键词 大破口LOCA喷放模拟 启动方式 压力精度 压力爬升速度 射流破坏实验 Large LOCA blowdown simulation Starting modes Pressure accuracy Pressure rise velocity Jet impinging destruction tests
  • 相关文献

参考文献2

二级参考文献13

  • 1U.S.NRC.Assessment of Debris Accumulation on PWR Sump Performance,Section 3. NUREG- 0933 . 1999 被引量:1
  • 2U.S.NRC.Water Sources for Long-Term Recirculation Cooling Following a Loss-of-Coolant Accident,RG1.82,Revision 3. . 2003 被引量:1
  • 3NEI.Pressurized Water Reactor Sump Performance Evaluation Methodology. NEI 04-07 . 2004 被引量:1
  • 4NEI.Safety Evaluation by NRC to GL2004-02 and Guidance Report. NEI 04-07 . 2004 被引量:1
  • 5Westinghouse.Evaluation of Downstream Sump Debris Effects in Support of GSI-191. WCAP-16406-P Revision 1 . 2007 被引量:1
  • 6U.S.NRC.U.S.Nuclear Regulatory Commission Safety Evaluation on WCAP-16406-P Revision 1. . 2007 被引量:1
  • 7Westinghouse.Evaluation of Long-Term Cooling Considering Particulate,Fibrous and Chemical Debris in the Recirculating Fluid. WCAP-16793-NP . 2007 被引量:1
  • 8U.S.NRC.Closure Options for GSI-191,Assessment of Debris Accumulation on Pressurized Water Reactor Sump Performance. SECY-2010-0113 . 2010 被引量:1
  • 9US.NRC.Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors. Generic Letter 04-02 . 2004 被引量:1
  • 10U.S.NRC.Potential Impact of Debris Blockage on Emergency Recirculation during Design Basis Accidents at Pressurized-Water Reactors. Generic Letter 04-02 . 2004 被引量:1