摘要  对聊古一井数字化氡观测资料进行分析研究的结果显示,科学合理的气水分离装置对于获得真实可靠的观测结果具有重要作用;保障仪器的正常工作状态,是数字化氡观测的重要环节之一。聊古一井数字化氡的变化特征主要受气温、气压和井压的影响,分析和排除这些因素的影响是数字化观测资料分析应用的基础。 The results of an analysis and study of the data of digital radoncontent observations at Liaogu No.1 well show that a scientific and reasonable gaswater separation device palys an improtant role in obtaining real and reliable observation results and ensuring the normal operational state of the instrument is one of the important links in the digital radoncontent observations. The characteristics of the variations in the digital radoncontent observation results of Liaogu No.1 well are mainly affected by atmospheric temperature, atmospheric pressure and well pressure. It is the basis of the analysis and application of the digital observational data to analyse and eliminate the influences of these factors.
出处 《地震学刊》 CSCD 2002年第4期16-20,共5页 Journal of Seismology
基金 国家"十五"科技攻关课题(01 04 02)资助。
关键词 数字化氡 气温 气压 井压 气水分离装置 地震前兆 Liaogu No.1 well digital radon-content observation affecting factor