Comparison of 45- degree Kelman and 45- degree balanced phaco tip designs in torsional microcoaxial phacoemulsification 被引量:3

下载PDF
导出
摘要 AIMTo compare the intraoperative performance and postoperative outcome after microcoaxial torsional phacoemulsification using either a Kelman or balanced phaco tip.METHODSCataracts were treated using 2.2 mm microcoaxial torsional phacoemulsification using either a 45-degree mini-flared Kelman<sup>&#x000ae;</sup> or a 45-degree Intrepid<sup>&#x000ae;</sup> Balanced phaco tip. Intraoperative measurements included total ultrasound (US) time, cumulative dissipated energy (CDE), torsional US time, and balanced salt solution (BSS) use. The central endothelial cell density (ECD) and central corneal thickness (CCT) were evaluated preoperatively and postoperatively 1, 7, and 30d after surgery using noncontact specular microscopy.RESULTSThe 116 enrolled eyes (116 patients) were divided equally between the Kelman and balanced tip groups. Intraoperative measurements showed significantly less total US time, torsional US time, CDE, and BSS use in the balanced group than in Kelman group (P&#x0003c;0.05). The total US time, torsional US time, CDE, and BSS use were 17.45&#x000b1;14.53s, 16.63&#x000b1;13.97s, 6.38&#x000b1;5.26, and 48.21&#x000b1;17.21 mL in the Kelman group and 11.39 &#x000b1; 9.60s, 10.90 &#x000b1; 9.25s, 4.04 &#x000b1; 3.42, and 41.36 &#x000b1; 12.70 mL in the balanced group, respectively.CONCLUSIONTorsional phacoemulsification performed with a balanced tip provided more effective lens removal with less total US time, torsional time, CDE, and BSS use, as well as similar changes in ECD with a Kelman tip in all cataract grades. This special designed phaco tip for torsional phacoemulsification provides an alternative phaco tip for many surgeons' preference with straight phaco tip. AIMTo compare the intraoperative performance and postoperative outcome after microcoaxial torsional phacoemulsification using either a Kelman or balanced phaco tip.METHODSCataracts were treated using 2.2 mm microcoaxial torsional phacoemulsification using either a 45-degree mini-flared Kelman<sup>&#x000ae;</sup> or a 45-degree Intrepid<sup>&#x000ae;</sup> Balanced phaco tip. Intraoperative measurements included total ultrasound (US) time, cumulative dissipated energy (CDE), torsional US time, and balanced salt solution (BSS) use. The central endothelial cell density (ECD) and central corneal thickness (CCT) were evaluated preoperatively and postoperatively 1, 7, and 30d after surgery using noncontact specular microscopy.RESULTSThe 116 enrolled eyes (116 patients) were divided equally between the Kelman and balanced tip groups. Intraoperative measurements showed significantly less total US time, torsional US time, CDE, and BSS use in the balanced group than in Kelman group (P&#x0003c;0.05). The total US time, torsional US time, CDE, and BSS use were 17.45&#x000b1;14.53s, 16.63&#x000b1;13.97s, 6.38&#x000b1;5.26, and 48.21&#x000b1;17.21 mL in the Kelman group and 11.39 &#x000b1; 9.60s, 10.90 &#x000b1; 9.25s, 4.04 &#x000b1; 3.42, and 41.36 &#x000b1; 12.70 mL in the balanced group, respectively.CONCLUSIONTorsional phacoemulsification performed with a balanced tip provided more effective lens removal with less total US time, torsional time, CDE, and BSS use, as well as similar changes in ECD with a Kelman tip in all cataract grades. This special designed phaco tip for torsional phacoemulsification provides an alternative phaco tip for many surgeons' preference with straight phaco tip.
机构地区 Eye Clinic
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第6期1168-1172,共5页 国际眼科杂志(英文版)
  • 相关文献

参考文献1

二级参考文献15

  • 1Ken Hayashi,Motoaki Yoshida,Shin-ichi Manabe,Akira Hirata.Cataract surgery in eyes with low corneal endothelial cell density[J]. Journal of Cataract & Refractive Surgery . 2011 (8) 被引量:2
  • 2Tracy Swartz,Lisa Marten,Ming Wang.Measuring the cornea: the latest developments in corneal topography[J]. Current Opinion in Ophthalmology . 2007 (4) 被引量:2
  • 3William J. Fishkind.The phaco machine: analysing new technology[J]. Current Opinion in Ophthalmology . 2013 (1) 被引量:1
  • 4Maged Maher Salib Roshdy,Assaf.Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision[J]. Clinical Ophthalmology . 2013 (default) 被引量:1
  • 5Daniele Tognetto,Paolo Cecchini,Pia Leon,Marta Di Nicola,Giuseppe Ravalico.Stroke dynamics and frequency of 3 phacoemulsification machines[J]. Journal of Cataract & Refractive Surgery . 2012 (2) 被引量:1
  • 6Mohamed Mahdy,Hafez,Mohammed,Bhatia,Eid.Relationship between endothelial cell loss and microcoaxial phacoemulsification parameters in noncomplicated cataract surgery[J]. Clinical Ophthalmology . 2012 (default) 被引量:1
  • 7Panos G. Christakis,Rosa M. Braga-Mele.Intraoperative performance and postoperative outcome comparison of longitudinal, torsional, and transversal phacoemulsification machines[J]. Journal of Cataract & Refractive Surgery . 2011 (2) 被引量:1
  • 8Bokkwan Jun,John P. Berdahl,Terry Kim.Thermal study of longitudinal and torsional ultrasound phacoemulsification[J]. Journal of Cataract & Refractive Surgery . 2010 (5) 被引量:1
  • 9Joseph S. Schmutz,Randall J. Olson.Thermal Comparison of Infiniti OZil and Signature Ellips Phacoemulsification Systems[J]. American Journal of Ophthalmology . 2010 (5) 被引量:1
  • 10Anna Reuschel,Holger Bogatsch,Thomas Barth,Renate Wiedemann.Comparison of endothelial changes and power settings between torsional and longitudinal phacoemulsification[J]. Journal of Cataract & Refractive Surgery . 2010 (11) 被引量:1

共引文献6

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部