摘要
用酸碱指示剂滴定法测定废水中的 OH-、CO2 -3 和 HCO-3 碱度时 ,S2 -对测定有干扰。此干扰可用 H2 O2 掩蔽。
In the case of applying acid-base indicator titration to determining wastewater's basicity of OH -?CO 2- 3 and HCO - 3 ,S 2- presents an interference which can be eliminated by means of H 2O 2 masking.
出处
《石油化工环境保护》
2002年第4期45-48,共4页
Environment Protection in Petrochemical Industry