随着分布式光伏产业的快速发展,电网企业受理的居民和企业用户光伏并网业务逐步增加,与此同时,由于分布式光伏发电并网方式的多样性,如何准确计量分布式光伏的相关电量参数,是光伏接入电网可靠运行的关键。文章依据当前分布式光伏相关政策,分析了不同消纳模式下分布式光伏接入和计量方案,并对不同方式下的计量方案配置进行对比分析,对分布式光伏的建设提供一定的指导意义。
With the rapid development of the distributed photovoltaic industry,the number of residential and corporate photovoltaic grid-connected businesses handled by power grid enterprises is gradually increasing.At the same time,due to the diversity of grid connection methods for distributed photovoltaic power generation,accurately measuring the relevant electricity parameters is crucial for the reliable integration of photovoltaics into the power grid.Based on the current policies related to distributed photovoltaics,this article analyzes the access and metering schemes of distributed photovoltaics under different consumption modes,and compares and analyzes the configuration of measurement schemes under different modes,providing certain guidance for the construction of distributed photovoltaics.
作者
向奕同
胡霆
黄宇翔
XIANG Yitong;HU Ting;HUANG Yuxiang(Shibei Power Supply Branch of State Grid Chongqing Electric Power Company,Chongqing Yubei 401147,China;Wanzhou Power Supply Branch of State Grid Chongqing Electric Power Company,Chongqing Wanzhou 404100,China)
出处
《农村电气化》
2024年第11期113-116,共4页
Rural Electrification
关键词
分布式光伏
电量参数
计量方案
distributed photovoltaics
electricity parameters
metering schemes