期刊文献+

基于工程实例的倒置式屋面渗漏原因分析与维修处置

Leakage Cause Analysis and Maintenance of Inverted Roofs Based on Engineering Cases
下载PDF
导出
摘要 以北方冬冷地区某倒置式屋面实际工程案例为研究对象,重点阐述了倒置式屋面渗漏问题产生的各方面原因、维修施工方案技术要点及质量控制措施;对原渗漏屋面进行局部开挖,排除构造层内积水,加设双层排汽管系统,最后整体设置4 mm厚SBS改性沥青防水卷材+1.5 mm厚非固化橡胶沥青涂料复合防水层,维修后屋面效果良好。 Taking a practical engineering case of an inverted roof in the cold winter region of northern China as the research object,this paper focuses on various reasons for the leakage problem of inverted roofs,the technical points of maintenance and construction plans,and quality control measures.Partial excavation is carried out on the original leaking roof to remove the accumulated water in the structural layer,and a double-layer exhaust pipe system is added.Finally,a combined waterproofing layer of 4 mm thick SBS modified bitumen waterproofing membrane and a 1.5 mm thick non-solidified rubber asphalt coating is installed as a whole.The repair effect of the roof is good.
作者 王彦朋 张恒 尚英杰 Wang Yanpeng;Zhang Heng;Shang Yingjie(School of Architecture and Geomatics Engineering,Shanxi Datong University,Datong,Shanxi037003,China;Yanlord Land Group Limited,Shanghai200127,China)
出处 《中国建筑防水》 2024年第10期48-52,共5页 China Building Waterproofing
基金 山西大同大学基础青年科研基金项目(2022Q35)。
关键词 北方冬冷地区 倒置式屋面 渗漏原因 维修方案 双层排汽管 泡沫混凝土 cold winter regions in the north inverted roof leakage cause maintenance plan double layer exhaust pipe cellular concrete