摘要 通过分析新能源场站采用π型接入和T型接入2种方案,评估它们对现有电网稳定性和传输效率的影响。文章首先概述2种接入方式的技术原理;其次,探讨2种方案的经济效益和工程实现难度,为不同条件下选择新能源接入方式提供决策参考;最后,提出一些建议和改进措施,以优化新能源接入策略,平衡经济效益与电网稳定性。 By comparing and analyzing theπ-type access and T-type access schemes adopted by new energy stations,evaluate their impact on the stability and transmission efficiency of the existing power grid.The article first outlines the technical principles of two access methods;Secondly,the economic benefits and engineering implementation difficulties of the two schemes were discussed,providing decision-making references for selecting new energy access methods under different conditions;Finally,some suggestions and improvement measures were proposed to optimize the new energy access strategy,balance economic benefits and grid stability.
作者 毕京斌 丁斌 王佩玲 BI Jingbin;DING Bin;WANG Peiling(Shandong Luzhong Electric Power Engineering Design Co.,Ltd.,Jinan 250100,China)
出处 《通信电源技术》 2024年第6期216-218,共3页 Telecom Power Technology
关键词 新能源接入 电网影响 π型接入 T型接入 传输效率 经济效益 new energy access power grid impact π-type access T-shaped access transmission efficiency economic benefits