期刊文献+

某600MW机组锅炉主汽出口抽汽方案安全性分析

Safety analysis of steam extraction scheme for boiler main steam outlet of a 600MW unit
下载PDF
导出
摘要 供热抽汽是形势所趋,本文以某60万千瓦锅炉主汽出口管道最大抽汽量方案进行核算,分别就30%、40%和50%锅炉负荷、在保证发电量不变的基础上,通过壁温计算模型的建立,最终理论计算出三个负荷下最大的理论抽汽量,可为后续供热抽汽改造方案设计提供一些参考。 Heating steam extraction is the trend of the situation,in this paper,the maximum steam extraction scheme of the main steam outlet pipeline of a 600,000-kilowatt boiler is calculated,respectively on the basis of 30%,40%and 50%boiler load,and on the basis of ensuring the constant power generation,through the establishment of the wall temperature calculation model,the final theoretical calculation of the maximum theoretical steam extraction amount under the three loads.It can provide some references for the subsequent design of the heat supply steam extraction reform scheme.
作者 龙志云 王慧文 户洋洋 王建伟 LONG Zhiyun;WANG Huiwen;HU Yangyang;WANG Jianwei(Harbin Boiler Company Limited,Harbin 150046,China)
出处 《锅炉制造》 2024年第3期4-6,共3页 Boiler Manufacturing
关键词 安全性分析 抽汽改造 壁温计算建模 security analysis Extraction steam transformation Wall temperature calculation modeling