摘要
针对变电站发生全停后开关状态无法识别而引发的问题,提出一种考虑配网实时运行方式的负荷转供技术。采用贝叶斯网络描述开关状态与节点电压的关系,识别配网的拓扑运行状态进而作为转供方案的基础。最后通过对某个实际配电系统的故障仿真分析,结果表明该方案可以有效提高停电负荷的转供能力。
Aims at the problem that the switch state cannot be identified after the complete shutdown of the substation,this paper proposes taking into account the frequent topology changes.Bayesian networks are used to describe the relationship between switch status and node voltage,identify the topology of the distribution network,and serve as the basis for the power transfer scheme;Finally,through fault simulation analysis of an actual distribution system,result can effectively increase the transfer capacity of power outage load.
作者
付俊强
吴磊
FU Junqiang;WU Lei(Hangzhou Jiuyi power Technology Co.,Ltd.,Zhejiang Hangzhou 310012,China;State Grid LuAn Power Supply Company,Anhui LuAn 237006,China)
出处
《农村电气化》
2024年第4期1-5,共5页
Rural Electrification
关键词
变电站全停
负荷转供
拓扑运行状态辨识
最大恢复供电能力
贝叶斯网络
shutdown of the substation
load transfer
topology operation recognition
maximum power recovery capacity
Bayesian network