摘要
以兰州某教育园区综合体育馆为例,介绍了综合体育馆在热源唯一的情况下根据综合体育馆建筑功能布置,同时考虑兰州位于西北寒冷地区的气候特点,在满足各功能分区设计参数的条件下,对整体采暖设计方案进行创新性优化,在同一建筑不同分区采用3种不同的采暖方式保证整体采暖系统,在满足实际使用需求的同时,达到经济合理、节能可靠的目的。
Taking a comprehensive stadium in a certain education park in Lanzhou as an example,this article introduces the innovative optimization of the overall heating design scheme based on the functional layout of the comprehensive stadinm under the condition of a single heat source while considering the climatic characteristics of Lanzhou located in the cold northwest region.Three different heating methods are adopted in different zones of the same building to ensure that the overall heating system meets the actual use requirements while being economically reasonable,technologically energy-saving,and reliable.
作者
冯坤旋
FENG Kunxuan(Lanzhou Engineering&Research Institute of Nonferrous Metallurgy Co.,Ltd.,Lanzhou 730000,China)
出处
《技术与市场》
2024年第3期79-82,共4页
Technology and Market
关键词
综合体育馆
采暖设计
低温地板辐射采暖
大空间采暖
comprehensive stadium
heating system design
low-temperature floor radiant heating
large space heating