摘要
目的 探究8~10岁儿童使用角膜塑形镜(Ortho-k)和周边离焦软镜(DISCs)对近视防控效果比较。方法 前瞻性非随机临床对照研究。将儿童分为Ortho-k组和DISCs组,观察其在近视防控方面的效果。观察两组患者的等效球镜(SE)及眼轴(AL)变化特点。结果 6月随访:两组的平均SE分别为(-3.30±1.27)D、(-3.09±1.31)D,平均AL分别为(24.83±0.89)mm、(24.75±0.94)mm。1年随访:两组的平均SE分别为(-3.49±1.24)D、(-3.32±1.29)D,平均AL分别为(24.96±0.88)mm、(24.92±0.92)mm。随访中:两组的SE和AL均有所增加,但差异无统计学意义。结论 本研究发现两种近视矫正方式在近视防控中具有相似疗效。
Objective The objective of this study was to compare the efficacy of orthokeratology lenses(Ortho-k)and Defocus Incorporated Soft Contact lens(DISCs)in the management and prevention of myopia in children aged 8-10.Methods A prospective non-randomized controlled study was conducted to evaluate the impact of these two interventions on myopia control.The participants were divided into two groups:the Ortho-k group and the DISCs group.Changes in spherical equivalent(SE)and axial length(AL)were measured and compared between the two groups.Results At the 6-month follow-up,the average SE in the Ortho-k group was(-3.30±1.27)D,with a mean AL of(24.83±0.89)mm.In the DISCs group,the average SE was(-3.09±1.31)D,with a mean AL of(24.75±0.94)mm.At the 1-year follow-up,the average SE in the Ortho-k group was(-3.49±1.24)D,with a mean AL of(24.96±0.88)mm.In the DISCs group,the average SE was(-3.32±1.29)D,with a mean AL of(24.92±0.92)mm.Both groups experienced an increase in SE and AL over the course of the follow-up period;however,these differences were not statistically significant.Conclusion This study demonstrates that both Ortho-k andDISCs have similar efficacy in managing and preventing myopia in children.
作者
吕耘
胡淋
张明玥
李君
杜川望
谢晓佳
Lv Yun;Hu Lin;Zhang Mingyue;Li Jun;Du Chuanwang;Xie Xiaojia(Fushun People’s Hospital,Zigong,Sichuan,643200)
出处
《中医眼耳鼻喉杂志》
2024年第1期30-32,共3页
Journal of Chinese Ophthalmology and Otorhinolaryngology
基金
自贡市科学技术局(重点科技计划项目):立项编号:2019ZC02。
关键词
近视
角膜塑形镜
周边离焦软镜
Myopia
Orthokeratology lenses
Defocus incorporated soft contact lens