摘要
输水管线设计的优劣在很大程度上决定着输水工程的效率和水资源利用水平,是城市水资源优化建设的基础保障。为保障居民饮用水安全,扩大供水规模,文章对石门台饮用水工程输水管线路作方案优选,探讨了该工程取水点和泵站位置的选择,在此基础上细致比选了输水管线A线、B线和C线的走线和输水管材,最终确定输水管线总长48.437 km,采用Q355材质的钢管。该城市输水管比选方案可为类似案例提供借鉴。
The quality of water conveyance pipeline design largely determines the efficiency of water conveyance engineering and the level of water resource utilization,which is the basic guarantee for the optimization construction of urban water resources.In order to ensure the safety of drinking water for residents and expand the scale of water supply,this paper optimizes the water conveyance pipeline scheme of Shimentai drinking water engineering,and discusses the selection of water intake point and pump station position of the engineering.On this basis,the routine and water conveyance pipe materials of water conveyance pipeline A,B and C are carefully compared and selected.Finally,the total length of water conveyance pipeline is determined to be 48.437 km,and the Q355 steel pipe is adopted.The comparison and selection scheme of the city's water conveyance pipeline can provide reference for similar cases.
作者
曾文樱
ZENG Wenying(Yingde Jucai Human Resources Service Co.,Ltd.,Qingyuan 513000,Guangdong,China)
出处
《工程技术研究》
2023年第17期189-191,共3页
Engineering and Technological Research
关键词
石门台
输水管线
方案比选
工程设计
Shimentai
water conveyance pipeline
scheme comparison and selection
engineering design