期刊文献+

Comprehensive evaluation and analysis of a nearly zero-energy building heating system using a multi-source heat pump in severe cold region 被引量:1

原文传递
导出
摘要 The integrated application of multi-energy coupled technology in nearly zero-energy building(NZEB)is promising from the perspective of low-carbon development to achieve the goal of net zero energy.PVT(photovoltaic/thermal),air,and ground sources were combined organically to establish an experimental platform of a multi-source heat pump(MSHP)system,which can realize flexible switching of multi-energy sources.The paper presents the analytical hierarchy process and fuzzy comprehensive evaluation method to comprehensively evaluate the five modes of the MSHP system with regard to energy,economic and environmental benefits.The results indicate that the waste heat of the PVT cavity can improve the coefficient of performance of the heat pump unit(COP)by approximately 8.0%.The initial investment in air source heat pump(ASHP)modes is lower than that of a coal-powered system.The ground source heat pump(GSHP)modes have high stability and their payback period is 8.81–10.66 years.The photovoltaic/thermal-dual source heat pump(PVT-DSHP)mode presents the most appropriate system applied in the NZEB in severe cold region,followed by the DSHP,GSHP,ASHP,and PVT-ASHP mode.When compared with other modes,COP,annual saving cost,carbon dioxide emission reduction,and comprehensive value of the PVT-DSHP mode have improved by 7.07%–29.57%,2.21%–23.88%,3.38%–14.83%,and 27.91%–52.62%,respectively.The study provides important insights into the practical application and sustainable development of multi-energy coupled systems in the NZEB in severe cold region.
出处 《Building Simulation》 SCIE EI CSCD 2023年第10期1949-1970,共22页 建筑模拟(英文)
基金 the National Key R&D Program of China“Research and Integrated Demonstration on Suitable Technology of Net Zero Energy Building”(No.2019YFE0100300) the National Natural Science Foundation of China(No.51778376) the Key Project of Education Department of Liaoning Province“Multi-objective Optimization Design and Key Technologies of Zero-Carbon and Zero-Energy Buildings in Cold Regions”(No.LJKZ0577) the Shenyang Science and Technology Planning Project“Research on Key Technologies of Multi-energy Coupling and Clean Emission Reduction of Zero-energy and Zero-carbon Buildings in Cold Regions”(No.21-108-9-03).
  • 相关文献

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部