采用酸析-微电解法预处理对甲砜基甲苯生产废水。考察了酸析pH、铁碳质量比、铁粉投加量、溶液pH及反应时间等因素对废水COD去除率的影响。结果表明,在酸析pH为2,铁碳质量比为2∶1,铁粉投加量为16 g/L,溶液pH为2,反应时间为3 h条件下处理效果最好,废水COD从70600 mg/L降至4521 mg/L,总去除率达到93.60%。
P-methylsulfone toluene production wastewater was pretreated by acid precipitation-microelectrolysis process.The effects of acid precipitation pH,iron/carbon mass ratio,iron powder dosage,solution pH and reaction time on COD removal were investigated.The results show that under the conditions of acid precipitation pH 2,iron/carbon mass ratio 2∶1,iron powder dosage 16 g/L,solution pH 2 and reaction time 3 h,the treatment effect is best.The COD of wastewater decreased from 70600 mg/L to 4521 mg/L and the total removal rate reached 93.60%.
作者
杨仁俊
张伟
赫瑞元
李鑫
韩萌
毋楠
龚文照
YANG Ren-jun;ZHANG Wei;HE Rui-yuan;LI Xin;HAN Meng;WU Nan;GONG Wen-zhao(Chemical Research Institute of Yangquan Coal Industry(Group)Co.,Ltd.,Taiyuan 030000,China)
出处
《应用化工》
CAS
CSCD
北大核心
2021年第S01期417-419,共3页
Applied Chemical Industry
关键词
对甲砜基甲苯
生产废水
酸析
微电解
P-methylsulfone toluene
production wastewater
acid precipitation