期刊文献+

核电站一回路主管道直接测温方案研究 被引量:2

Study on Direct Temperature Measurement Programme of Main Pipe of Primary Circuit of Nuclear Power Plant
下载PDF
导出
摘要 针对核电站一回路冷却剂温度测量,国内二代核电站中均采用了旁路管线测温方案,即在主管道上引入测温旁路管线。该方案已不能适应三代核电机组的要求。在三代核电设计中,取消了旁路管线设计,采用在主管道上直接测温的方式。针对测点布置、温度计数量等进行了分析优化,并针对一回路热管段的热分层效应,创新性地提出了测温搅混管嘴的设计。该设计能有效减少热管段热分层对测量准确度的影响。通过主管道内冷却剂流场和温度场的流体力学分析,得到优化后的一回路主管道直接测温方案。核电机组的实际运行结果表明,该方案能够准确、有效地测量一回路冷却剂温度,从而保障核电机组的安全、稳定运行。 For the measurement of coolant temperature in the primary circuit of nuclear power plant,the bypass pipeline temperature measurement programme has been adopted in the second⁃generation nuclear power plants in China,i.e,.the temperature measurement bypass pipeline is introduced in the main pipeline.This programme has not been able to adapt to the requirements of third⁃generation nuclear power units.In the design of third⁃generation nuclear power plant,the design of bypass line is canceled,and the way of direct temperature measurement on the main pipe is adopted.Analysis and optimization are carried out for the arrangement of measurement points and the number of thermometers,etc.,and the design of temperature measuring and mixing nozzle is innovatively put forward for the thermal stratification effect of the hot pipe section of the primary circuit.This design can effectively reduce the impact of thermal stratification of the heat pipe section on the measurement accuracy.Through the hydrodynamic analysis of the coolant flow field and temperature field in the main pipeline,the optimized direct temperature measurement program for the primary circuit main pipeline is obtained.The actual operation results of the nuclear power unit show that this programme can accurately and effectively measure the coolant temperature of the primary circuit,thus guaranteeing the safe and stable operation of the nuclear power unit.
作者 程超 田骏 宋磊 CHENG Chao;TIAN Jun;SONG Lei(Shenzhen China Nuclear Power Design Co,.Ltd,.Shenzhen 518045,China)
出处 《自动化仪表》 CAS 2023年第S01期357-360,共4页 Process Automation Instrumentation
关键词 一回路冷却剂 主管道 旁路管线 热分层 直接测温 测温组件 Primary circuit coolant Main pipeline Bypass pipeline Thermal stratification Direct temperature measurement Temperature measurement assembly
  • 相关文献

参考文献7

二级参考文献27

  • 1陆德民,张振基,黄步余.石油化工自动控制设计手册[M].3版.北京:化学工业出版社,2009. 被引量:4
  • 2曾酷昭,黄创霞,周富照.数值计算方法与应用[M].北京:科学出版社,2013. 被引量:2
  • 3Di PI.AZZA I. AP1000 RNS line-thermal strat fication analysis, APP-RCS M3C-043 [R/OL] [S. 1.]: [s. n.], 2012. 被引量:1
  • 4IEC 60751-2008. Industrial platinum resistance thermo- meters and platinum temperature sensors [S]. Geneva, International Electrotechnical Commission, 2008. 被引量:1
  • 5RCC-E压水堆核电站核岛电气设备设计和建造规则[s].3版.核工业第二研究设计院,1993. 被引量:1
  • 6法国核岛设备设计、建造及在役检查规则协会.RCC-M压水堆核岛机械设备设计和建造规则[s].中科华核电技术研究院有限公司,译,2007. 被引量:1
  • 7IEC 60751-2008. Industrial Platinum Resistance Thermometers and Platinum Temperature Sensors IS]. Geneva, International Electrotechnical Commission, 2008. 被引量:1
  • 8曾艚昭.神经计算原理及其应用技术[M].北京:科学出版社,2012. 被引量:1
  • 9周绍志,崔文德.铂电阻温度传感器封装结构影响响应时间的因素[J].导弹与航天运载技术,2009(3):29-31. 被引量:16
  • 10杨洪,林大伟,张宏礼.MATLAB中三个适于数据拟合命令的比较分析[J].大庆师范学院学报,2010,30(6):58-61. 被引量:3

共引文献17