期刊文献+

前置式蒸汽冷却器管系泄漏检测研究

Study on Detection of Tube Leakage in Front Steam Cooler
下载PDF
导出
摘要 前置式蒸汽冷却器是电站回热系统中的一个重要设备,位于回热系统中给水流程的最后一级,它利用中压抽汽的过热度加热给水,进一步提高进入省煤器的给水温度。其正常运行时壳侧无液位,它的疏水方式、泄漏检测与常规的高压加热器不同。本文阐述了前置式蒸汽冷却器管系泄漏的类型和危急疏水排放类型,结合前置式蒸汽冷却器运行特点,提出了采用温差检测换热管泄漏的方法,简述了温差检测管系泄漏的原理,组成和优点。 The front steam cooler is an important equipment in the regenerative system of power station.It is located in the last stage of the feed water flow in the regenerative system.It uses the superheat of Medium-pressure extraction steam to heat the feed water.In normal operation,there is no drain in the shell,and its drainage mode and pipeline leakage detection are different from high-pressure heaters.The article describes the types of tubes leakage and emergency drainage of the pre-steam cooler.Combined with the operation characteristics of the front steam cooler,the method of detecting the tubes leakage by using temperature difference is proposed.The principle,composition and advantages of the method are briefly described.
作者 樊进国 邓科 季敏东 Fan Jinguo;Deng Ke;Ji Min-dong(Dongfang Boiler Group Co.,Ltd.Chengdu,Sichuan,611731,China)
出处 《装备制造与教育》 2023年第3期10-13,共4页 Equipment Manufacturing and Education
关键词 蒸汽冷却器 温差 爆管 管系泄漏 控制 steam cooler temperature difference tube explosion tubes leakage control
  • 相关文献

参考文献3

  • 1董卫国,徐则民编著..火电厂给水加热器的运行、维护和检修[M].北京:中国电力出版社,1997:254.
  • 2杨世铭,陶文铨编著..传热学[M].北京:高等教育出版社,2006:591.
  • 3蔡锡琮编著..高压给水加热器[M].北京:水利电力出版社,1995:381.