期刊文献+

南水北调解台站节制闸液压启闭机改造技术探讨 被引量:2

Discussion on reconstruction technology of hydraulic hoist for control gate at mediation station of South-to-North Water Diversion
下载PDF
导出
摘要 针对南水北调解台站节制闸液压启闭机启门力不足与纠偏困难的问题,从多个角度深入分析了原因。研究结果表明:解台站节制闸两侧水位差较大,闸门开启时流速较快,导致实际启闭时存在较大的下吸力,闸门实际启闭所需的力远大于原设计值,液压系统管路中存在较大背压,也降低了启闭机的工作效率。基于上述原因,提出了加大启闭力与优化管路设计的解决措施,针对闸门的纠偏困难,改进了阀组设计,确保闸门提升过程的同步要求。研究成果可为同类工程液压式叶调结构优化设计提供参考。 In view of the problems of insufficient opening force and difficulty in rectifying deviation of the hydraulic hoist of the control gate at the mediation station of south-to-north water diversion,the reasons are analyzed from various angles.The research results show that the water level difference on both sides of the control gate at Jietai Station is large,and the flow velocity is fast when the gate is opened,resulting in a large downward suction force when the gate is actually opened and closed.The force required for the actual opening and closing of the gate is far greater than the original design value,and there is a large back pressure in the hydraulic system pipeline,which also reduces the working efficiency of the hoist.Based on the above reasons,the solution measures of increasing the lifting force and optimizing the pipeline design are put forward.Aiming at the difficulty of gate deviation correction,the valve group design is improved to ensure the synchronous requirements of gate lifting process.The research results can provide a reference for the optimization design of hydraulic blade adjusters in similar projects.
作者 于贤磊 鲁健 倪春 荐威 张苗 陈齐 YU Xianlei;LU Jian;NI Chun;JIAN Wei;ZHANG Miao;CHEN Qi(The Eastern Route of South-to-North Water Diversion Project Jiangsu Water Source Co.,Ltd.,Nanjing 210019,China)
出处 《江苏水利》 2023年第7期59-62,共4页 Jiangsu Water Resources
关键词 南水北调 节制闸 液压启闭机 South-to-North Water Diversion control gate hydraulic hoist
  • 相关文献

参考文献3

二级参考文献23

共引文献13

同被引文献17

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部