摘要
The non-cascade permanent magnet synchronous motor control system has the advantages of simple structure and less adjustable parameters,but the non-cascade structure needs to solve the problem of over-current protection.In this paper,a current constrained control method is used to limit the starting current to a safe range.At the same time,to ensure the robustness and rapidity of the system,a super twist current constraint controller(CCSTA)is generated by combining super twist algorithm(STA)with current constraint control;Considering the diversity of internal and external disturbances,a functional disturbance observer(FDOB)is proposed to compensate the matched and unmatched disturbances,which further improves the robustness of the system.