摘要
某地产地热供暖水源热泵系统对深层地热水进行封闭循环使用,即提取所抽地热水中能量之后将其全部回灌入相同的含水层,实现同层回灌。文章分析项目所在区域水文地质条件、地热资源储量、地热资源开发利用现状和水资源开发利用现状的基础上,分析项目供热需求的合理性,计算地热供暖的合理取水量,论证取用深层地热水和回灌对区域水资源的影响,提出水资源保护措施和建议,为其合理取用深层地热水提供可靠的技术依据。
A certain real estate geothermal heating water source heat pump system uses a closed-loop system to circulate deep geothermal water.This involves extracting energy from the extracted geothermal water and then injecting it back into the same aquifer,achieving intra-aquifer reinjection.This paper analyzes the hydrogeological conditions,geothermal resource reserves,current status of geothermal resource development and utilization,and current status of water resource development and utilization in the project area.Based on this,the paper analyzes the rationality of the project's heating demand,calculates the reasonable amount of water to be used for geothermal heating,and demonstrates the impact of using deep geothermal water and reinjection on the regional water resources.The paper proposes water resource protection measures and suggestions,providing reliable technical support for the reasonable use of deep geothermal water.
作者
耿华
张霞
王亚娟
GENG Hua;ZHANG Xia;WANG Yajuan(Jiyuan Water and Soil Conservation Monitoring Station,Jiyuan 459000,China;Water Affairs Center of Yangzhuang Detention Zone in Zhumadian City,Zhumadian 463000,China;Xincai County Water Conservancy Construction Project Quality Supervision Station,Xincai 463500,China)
出处
《河南水利与南水北调》
2023年第4期40-41,共2页
Henan Water Resources & South-to-North Water Diversion
关键词
房地产
水资源
水平年
取水影响论证
real estate
water resources
level year
water intake impact demonstration