期刊文献+

新型515kV直流SF_(6)气体绝缘穿墙套管研发设计

Development and Design of New 515 kV DC SF_6 Gas Insulated Wall Bushing
下载PDF
导出
摘要 直流穿墙套管是承载系统安全的一个核心设备,在直流输电系统中处于咽喉位置,文中以515 kV SF_(6)气体绝缘结构穿墙套管为研究对象,针对超长导电杆挠度过大引起穿墙套管内部电场畸变的问题,新设计一种带空间支撑结构的导电杆,并与传统导电杆对比分析,得到新型导电杆挠度值下降了34.95%,然后对安装新型导电杆的穿墙套管进行温升仿真分析,计算结果表明,安装新型导电杆的穿墙套管具备额定通流6515 A和耐受1550kV雷电冲击的能力。各项型式试验的顺利通过,验证了515kV SF_(6)气体绝缘结构穿墙套管结构的合理性,为直流输电工程更高电压等级穿墙套管的研制奠定理论基础。 DC wall bushing,which is located at the throat position in the DC transmission system,is a core equip?ment for carrying the safety of power system.In this paper,the 515 kV SF_6 gas insulated wall bushing is taken as the research object.Aiming at the problem of the electric field distortion in the wall bushing due to the excessive deflec?tion of ultra?long conductive rod,a kind of new conductive rod with space support structure is designed.Compared with the traditional conductive rod,the deflection of the new conductive rod decreases by 34.95%.Then,the temper?ature rise simulation analysis on the wall bushing installed with the new conductive rod is carried out.The calcula?tion results show that the wall bushing installed with the new conductive rod has the ability to pass through the cur?rent at 6 515 A and withstand lightning impulse at 1 550 kV.The success of various of type tests has verified ratio?nality of the structure of 515 kV SF_6 gas insulated wall bushing,which lays a theoretical foundation for the develop?ment of higher voltage level wall bushing for DC transmission projects.
作者 孙龙勇 姚灿江 刘英英 佟志鹏 杨光 高炳灿 李森然 SUN Longyong;YAO Canjiang;LIU Yingying;TONG Zhipeng;YANG Guang;GAO Bingcan;LI Senran(Henan Pinggao Electric Co.,Ltd.,Henan Pingdingshan 467001,China)
出处 《高压电器》 CAS CSCD 北大核心 2023年第5期28-34,共7页 High Voltage Apparatus
关键词 直流穿墙套管 导电杆 电场强度 挠度值 DC wall bushing conductive rod electric field strength deflection value
  • 相关文献

参考文献29

二级参考文献317

共引文献444

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部