摘要 风振系数是输电杆塔结构设计中非常关键的参数,但是国内外设计规范的风振系数计算公式均比较复杂,研究基于惯性力法,对输电杆塔风振系数计算方法进行推导优化,并对影响参数进行了分析。研究结果简化了计算过程,计算结果准确,为输电杆塔风振系数的计算提供了一种更高效的新思路。 Wind-induced vibration coefficient is a key parameter in the structural design of transmission towers.However,the calculation formulas of wind-induced vibration coefficient in design codes at home and abroad are complicated.Based on the inertia force method,the calculation method of wind-induced vibration coefficient of transmission towers is deduced and optimized,and the influencing parameters are analyzed.The research results simplify the calculation process and are accurate,which provides a more efficient new idea for the calculation of windinduced vibration coefficient of transmission towers.
作者 吴广 WU Guang(Hunan Economy Institute Electric Power Design Co.,Ltd.,Changsha 410000,China)
出处 《通信电源技术》 2023年第4期67-69,73,共4页 Telecom Power Technology
关键词 输电杆塔 风振响应 风振系数 横担 惯性力法 transmission tower wind-induced vibration response wind-induced vibration coefficient cross arm inertial force method