期刊文献+

外侧壁破裂股骨粗隆间骨折三种内固定有限元分析 被引量:3

A finite element analysis on three kinds of internal fixation for femoral intertrochanteric fracture with lateral wall fracture
原文传递
导出
摘要 [目的]比较三种内固定外侧壁破裂型股骨粗隆间骨折的力学特性。[方法]自1名志愿者采集股骨CT图像,在Mimics14.0、Geomagic Studio、CERO3.0、Hypermesh13.0软件处理,分别构建外侧壁破裂型股骨粗隆间骨折的PFNA、PFNA张力带和锁定钢板内固定模型。在Abaqus6.12中加载,分析内固定及骨折端应力和位移变化。[结果]三种内固定模式的Von Mises应力由大至小依次为颈干交界>股骨头区>骨折区,差异有统计学意义(P<0.05)。股骨头区Von Mises应力由大至小依次为PFNA>PFNA张力带>锁定钢板,差异有统计学意义(P<0.05);骨折区Von Mises应力三组间差异均无统计学意义(P>0.05);颈干交界区Von Mises应力由大至小依次为PFNA>锁定钢板>PFNA张力带,差异有统计学意义(P<0.05)。三种固定物骨折端位移由小至大依次为PNFA张力带<锁定钢板<PFNA(P<0.05)。[结论]PFNA联合张力带固定治疗外侧壁破裂型股骨粗隆间骨折,能够减小应力和位移,有利于骨折端稳定。 [Objective] To compare the mechanical properties of three kinds of internal fixation for femoral intertrochanteric fractures with lateral wall fracture. [Methods] The CT images of femur were obtained from a volunteer and processed by MIMICS14.0, Geomagic Studio, CERO3.0, Hypermesh13.0 software to create the models of proximal femoral nail anti-rotation(PFNA), PFNA enhanced by tension band and locking plate as internal fixation fore femoral intertrochanteric fractures with ruptured lateral wall respectively. The Von Mises stress and displacement of the implant and fractures were analyzed by using Abaqus6.12. [Results] All the Von Mises stresses of the three internal fixation modes were in descending order as the neck-trunk junction > femoral head > fracture site, with statistically significant differences(P<0.05). The Von Mises stress in femoral head was in descending order as PFNA > PFNA-tension band > locking plate with a statistically significant difference among them(P<0.05), whereas which proved not significantly different in the fracture site among the three groups(P>0.05), and were significantly ranked up-down in neck-trunk junction as PFNA > Locking plate > PFNA-tension band(P<0.05). Conversely, displacements of fracture ends were significantly arranged down-up in order of PNFA-tension band < locking plate < PFNA(P<0.05). [Conclusion] PFNA enhanced by tension band fixation does reduce the stress and displacement of femoral intertrochanteric fracture complicated with lateral wall fracture, which is beneficial to the stability of fracture ends.
作者 赵豪 高山 陈庭瑞 ZHAO Hao;GAO Shan;CHEN Ting-rui(Department of Joint Surgery,Central Hospital of Zhumadian City,Zhumadian 463000,China;Department of Traumatic Orthopaedics,Central Hospital of Zhumadian City,Zhumadian 463000,China)
出处 《中国矫形外科杂志》 CAS CSCD 北大核心 2023年第6期538-542,共5页 Orthopedic Journal of China
关键词 股骨粗隆间骨折 外侧壁破裂 股骨近端防旋髓内钉 张力带 锁定钢板 femoral intertrochanteric fractures lateral wall rupture proximal femoral nail anti-rotation tension band locking plate
  • 相关文献

参考文献9

二级参考文献114

  • 1朱江涛,卫小春.股骨粗隆间骨折分型[J].实用骨科杂志,2007,13(7):410-413. 被引量:69
  • 2Evans E. The treatment of trochanteric fractures of the femur. J Pone Joint Surg Br. 1949. 31(2): 190-203. 被引量:1
  • 3Jensen JS, Classification of trochanteric fractures. Acta Orthop Scand, 1980, 51 (5) :803-810. 被引量:1
  • 4Baumgaertner MR. Curtin SL. lindskog DM, et al. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures af the hip. J Pone Jaint Surg fun. 1995.77(7) :1058-1064. 被引量:1
  • 5Parker lVU. Trochanteric hip fractures. Fixation failure oommoner with femoral medialization, a oomparison of 101 cases. Acta Orthop Scand, 1996, 67(4) :329- 332. 被引量:1
  • 6Gotfried Y. The lateral trochanteric wall: a key element in the reconstruction of unstable pertrochanteric hip fractures. Clin Orthop Relat Res. 2004. 425:82-86. 被引量:1
  • 7Palm H, Jaoobsen S, Sonne- Holm S, et al. Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation, J Pone Joint Surg fun. 2007, 89(3) :470-475. 被引量:1
  • 8Gotfried Y. Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation, J Pone Joint Surg fun, 2007, 89(11): 2552-2553. 被引量:1
  • 9Irn GI, Shin YW. Song YJ. Potentially unstable intertrochanteric fractures. J Orthop Thuma. 2005. 19(1) :5-9. 被引量:1
  • 10Babst R, Renner N. Bedermann M, et al. Clinical results using the trochanter stabilizing plate(TSP): the modular extension of the dynamic hip screw(DHS) far internal fixation of selected unstable intertrochanteric fractures. J Orthop Trauma, 1998, 12(6) :392-399. 被引量:1

共引文献166