期刊文献+

新型冠状病毒抗原检测诊断效能和临床应用评价 被引量:2

Diagnostic efficacy and clinical application evaluation of SARS-CoV-2 antigen determination
下载PDF
导出
摘要 目的探讨新型冠状病毒(SARS-CoV-2)抗原检测的临床应用价值及其诊断效能。方法随机选取2022年3—6月上海市松江区某方舱无症状SARS-CoV-2感染初期患者340例、某封控小区居民4294名、某管控小区居民420名、某防范小区居民800名进行SARS-CoV-2抗原检测,采用核酸双试剂复核SARS-CoV-2抗原阳性结果。采用受试者工作特征(ROC)曲线评价SARS-CoV-2抗原检测诊断SARS-CoV-2感染的效能。结果方舱SARS-CoV-2感染患者进舱第1天抗原检测阳性率为81.0%。封控小区和管控小区居民抗原检测真阳性率平均为43.1%。核酸检测阳性率明显高于抗原检测真阳性率(P<0.01),2种检测方法的一致性较差(Kappa=0.266)。SARS-CoV-2阳性患者抗原转阴时间显著早于核酸转阴时间(P<0.05),且循环阈值(Ct)>28时抗原试剂检测线(T线)不显色。ROC曲线分析结果显示,SARS-CoV-2抗原检测诊断SARS-CoV-2感染的曲线下面积为0.773。结论SARS-CoV-2抗原检测可用于SARS-CoV-2的筛查,但不能替代核酸检测。 Objective To investigate the clinical application value and diagnostic efficacy of severe acute respiratory syndrome coronavirus 2(SARS-CoV-2)antigen determination.Methods From March to June 2022,340 asymptomatic patients at the initial stage of corona virus disease 2019(COVID-19)in a shelter in Songjiang District,4294 residents in a sealed control area,420 residents in a management control area and 800 residents in a prevention area were randomly enrolled for the determination of SARS-CoV-2 antigen.The positive SARS-CoV-2antigen determination results were rechecked with double-reagent nucleic acid.Receiver operating characteristic(ROC)curve was used to evaluate the efficiency of SARS-CoV-2 antigen qualitative determination for the diagnosis of SARS-CoV-2 infection.Results The positive rate of SARS-CoV-2 antigen determination on the first day of shelter was 81.0%,and the average true positive rate of SARS-CoV-2 antigen determination in sealed control area and management control area was 43.1%.The positive rate of nucleic acid test was higher than that of SARS-CoV-2antigen determination(P<0.01),and the consistency of the 2 methods was poor(Kappa value was 0.266).The turn-to-negative time of SARS-CoV-2 antigen determination was earlier than that of nucleic acid test(P<0.05),and the antigen determination line(T line)did not show colour when the cycle threshold(Ct)value was>28.The area under curve was 0.773 for SARS-CoV-2 antigen determination.Conclusions Antigen determination can be used as an auxiliary method in the early screening of SARS-CoV-2,but it can not replace nucleic acid test.
作者 杨丹平 王宏 王灿 陈卫 杨爱平 YANG Danping;WANG Hong;WANG Can;CHEN Wei;YANG Aiping(Shanghai Songjiang Jiuting Hospital,Shanghai 201615,China)
出处 《检验医学》 CAS 2023年第1期28-31,共4页 Laboratory Medicine
关键词 新型冠状病毒 抗原检测 核酸检测 诊断效能 Severe acute respiratory syndrome coronavirus 2 Antigen qualitative determination Nucleic acid test Diagnostic efficacy
  • 相关文献

参考文献10

二级参考文献46

共引文献142

同被引文献24

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部