摘要
对二甲苯联合装置(PX)吸附分离单元程控球阀作为装置的核心设备之一,动作频繁,寿命要求高,使用工况苛刻,内、外泄漏控制严格。程控球阀的故障将导致控制系统进入既定的容错程序,导致床层进出口物料流量和压力的波动,最终可能对吸附塔内构件造成严重的破坏和损伤,直接影响装置的安全高效运行。本文以福海创位号为43-XV-421程控球阀的成功应用为案例,探讨程控球阀常见故障原因分析及解决方案。
Xylene combined unit(PX) adsorption separation unit programmed ball valve as one of the core equipment of the device, frequent action, high life requirements, harsh working conditions, internal and external leakage control strict.The failure of program controlled ball valve will lead to the control system into the established fault tolerance procedure, resulting in bed inlet and outlet material flow and pressure fluctuations, ultimately may cause serious damage and damage to the adsorption tower internal components, directly affecting the safe and efficient operation of the device.In this paper, the successful application of Fuhai 43-XV-421 program control ball valve as a case, to explore the common fault analysis of program control ball valve and solutions.
作者
尚海泉
盛子烨
许义兵
SHANG Hai-quan;SHENG Zi-ye;XU Yi-bing(Wuxi Intelligent Automation Engineering Co.,LTD.,Wuxi 214000,Jiangsu,China)
出处
《阀门》
2023年第1期51-55,共5页
VALVE MAGAZINE
关键词
程控球阀
高频动作
配对研磨
分子筛
programmable ball valve
high frequency action
paired grinding
molecular sieve