摘要
根据国家节能减排总体要求,通过在既有地铁线路测试典型车站空调系统实际运行数据,分析传统中央空调系统能耗居高不下的原因,提出高效空调系统技术要求,选取一个既有站点进行试点改造后,经多方面分析、总结,成功在深圳地铁新线建设中全面推广应用。
According to national energy conservation and emission reduction requirements,the reasons for the high energy consumption of traditional air conditioning are analyzed by testing the actual operational data of airconditioning systems in typical stations on the existing metro lines,and the technical requirements of the high efficiency air conditioning system were put forward.An existing station was selected for pilot retrofitting,and it is later successfully popularized and applied in the construction of the new line of Shenzhen metro through various analysis and summarization.
出处
《现代城市轨道交通》
2023年第1期28-32,共5页
Modern Urban Transit
关键词
地铁
节能减排
能耗
高效空调系统
应用
metro
energy conservation and emission reduction
energy consumption
high efficiency air conditioning system