循环流化床锅炉运行问题分析及节能降耗优化探究 被引量:1

Study on Operation Problems of Circulating Fluidized Bed Boiler and Optimization of Energy-saving and Emission-reduction
下载PDF
导出
摘要 以某厂480 t/h循环流化床锅炉为例,列举了该锅炉运行中出现的问题,其中包括飞灰及底渣含碳量较高、燃煤粒度控制不合理、锅炉特征量监测不可靠、滚筒冷渣器排渣困难等,结合实际运行参数,提出了合理调整锅炉一、二次配风,合理配比入炉燃煤粒径,加强锅炉特征量测点维护工作,燃烧优化调整等相关措施,使锅炉能够长期安全、稳定、经济运行,为同类型锅炉节能降耗减排工作提供了有效参考。 The 480t/h circulating fluidized bed(CFB) boiler in a plant is taken as an example and the problems in the operation of the boiler are listed,including high carbon content of fly ash and bottom slag,unreasonable control of coal particle size,unreliable quantity monitoring of boiler characteristics,discharge difficulty of drum slag cooler,and so on. Based on actual operating parameters,relevant measures are put forward,such as reasonable adjustment of the boiler’s primary and secondary air distribution,reasonable proportion of coal particle size,reinforcement of the maintenance of the boiler’s characteristic measurement points,optimization and adjustment of combustion,etc.,so that the boiler can be in safe,stable and economic operation for a long time,which provides effective reference for energy-saving and emission-reduction of the same type of boiler.
作者 马守财 闫星磊 MA Shoucai;YAN Xinglei(Xiaoyi Coal Power Co.,Ltd.of Jinneng Holding Group,Xiaoyi,Shanxi 032300,China;Shanxi Shiji Zhongshi Power Science and Technology Co.,Ltd.,Taiyuan,Shanxi 030001,China)
出处 《山西电力》 2022年第6期47-51,共5页 Shanxi Electric Power
关键词 循环流化床锅炉 低渣含碳量 燃煤粒径 燃烧优化调整 节能降耗 CFB boiler low slag carbon content coal particle size optimization and adjustment of combustion energy-saving and emission-reduction
  • 相关文献

参考文献6

二级参考文献19

共引文献28

同被引文献14

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部