摘要 本文详细论述高速铁路、城际铁路、普速铁路、普速货运专用铁路的10kV配电所及配电系统的构成形式以及中性点接地差异特点,并对各种10kV配电所调压器中性点接地方式差异化进行电气原理分析。 This paper discusses in detail the composition of 10 kV power distribution station and distribution system of high-speed railway, intercity railway, universal railway and universal freight special railway, as well as the characteristics of neutral point grounding difference. It also analyzes the electrical principle of the difference of neutral point grounding mode of voltage regulator in various 10 kV power distribution station.
作者 姜同伍 孟军锋 梅振 刘铭洋 Jiang Tongwu;Meng Junfeng;Mei Zhen;Liu Mingyang(China Railway Wuhan Survey and Design Co.,Ltd,Wuhan 430000,China;China Railway Wuhan Group Co.,Ltd,Wuhan 430000,China)
出处 《智能建筑电气技术》 2022年第5期61-66,共6页 Electrical Technology of Intelligent Buildings
关键词 铁路配电所 贯通线 自闭线 中性点接地形式 不接地 小电阻接地 消弧线圈接地 railway distribution station well versed in line since the closed line neutral grounding form no grounding small resistance grounding arc suppression coil is grounded