摘要
介绍了某核电站机组柴油发电机励磁系统和同期装置存在的问题,包括励磁系统技术水平落后、励磁调节方式单一、设备老化、无人性化的人机交互窗口等。通过国产化改造,解决了机组柴油发电机励磁系统和同期装置存在的问题,提高了励磁系统和同期装置的稳定性、可靠性,开创了国产化机组柴油发电机励磁系统和同期装置在国内核电行业应用的先河。
A nuclear power plant unit diesel generator excitation system are introduced in this device,and the analysis of the nuclear power plant Alstom diesel generator excitation system provided by the device and the existing problems,including excitation system backward technology level,single excitation adjustment modes,equipment aging,without a humanized human-computer interaction window,etc.In order to solve the above problems,the domestic transformation has solved the problems existing in the excitation system and the synchronous device of the diesel generator set,improved the stability and reliability of the excitation system and the synchronous device,and created a precedent for the application of the excitation system and the synchronous device of the diesel generator set in the domestic nuclear power industry.
作者
朱永乐
车鹏
李栋
孟凡博
ZHU Yongle;CHE Peng;LI Dong;MENG Fanbo(Jiangsu Nuclear Power Corporation,Lianyungang 222000,China)
出处
《电工技术》
2022年第19期183-185,191,共4页
Electric Engineering
关键词
励磁系统
同期装置
电压调节
恒功率因数
excitation system
synchronizing device
voltage regulation
constant power factor