摘要
针对站用直流电源蓄电池的新旧混用问题、预防失效补救措施以及不同性能蓄电池集中管理、预防长期储存备件蓄电池失效的问题,文章从产生的历史、原因以及现状的各个角度进行阐明及分析,并提出了可行的实现方向及路线。
Aiming at the problem of mixed use of new and old batteries for station DC power supply,remedial measures to prevent failure,centralized management of batteries with different performances,and prevention of failure of batteries with long-term storage spare parts,the article clarifies and analyzes the history,reasons and current situation of the occurrence.And put forward the feasible direction and route of realization.
作者
宋涛
SONG Tao(Jiangmen Power Supply Bureau,Guangdong Power Grid Co.,Ltd.,Jiangmen 529000,China)
关键词
站用直流电源
蓄电池组
均浮充
新旧电池混用
备品蓄电池管理
DC power supply for station
battery pack
floating charge
mixed use of old and new batteries