期刊文献+

马蹄环式外固定架固定AO-C2型Pilon骨折在轴向载荷下的稳定性 被引量:3

Stability of Fixation for AO-C2 Pilon Fracture with Horseshoe Ring External Fixator under Axial Loading
下载PDF
导出
摘要 目的在传统环形外固定架构型基础上进行重新设计,使其更适合关节内Pilon骨折的固定。通过定量分析负重载荷下应用马蹄环形外固定架固定Pilon骨折端位移以验证该外固定架的稳定性。方法采用摆锯依据预先制定的截骨线制备AO-C2型Pilon骨折模型,应用马蹄环形外固定架对其固定,然后于力学加载机上进行轴向载荷力学加载。轴向载荷加载方式为从0 N开始依次加载至150、300、450 N。用动态捕捉仪记录轴向载荷加载过程中骨折块在X(左右)、Y(上下)、Z(前后)轴的移位变化。结果腓骨左右、上下、前后方向整体移位范围分别为0.32~0.70、-0.27~-0.23、0.23~0.32 mm,最大差值为0.09 mm。胫骨内踝侧骨折块左右、上下、前后方向整体移位分别为0.02~0.14、-0.80~-0.19、-0.78~-0.13 mm。胫骨外踝侧骨折块左右、上下、前后方向整体移位范围分别为-0.07~0.05、-0.36~-0.03、0.27~0.47 mm。结论马蹄环形外固定架不仅能实现骨折端的稳定固定且能产生有利于骨折愈合的微动,符合骨折愈合的生物力学特点。该外固定架构型简单,适合Pilon骨折的治疗,值得推广应用。 Objective The traditional circular external fixation structure was redesigned to make it more suitable for intraarticular Pilon fracture fixation.The stability of the horseshoe annular external fixator was verified by analyzing fracture displacement of the Pilon bone after fixation with the external fixator under loading.Methods AO-C2 Pilon fracture model was prepared by pendulum saw according to predetermined osteotomy line,and then fixed by horseshoe ring external fixator.The fixed ankle model was subjected to axial loading on mechanical test machine.The axial force loading mode was from 0 N to 150 N,300 N and 450 N successively.The displacement changes of fracture blocks in X(left-right),Y(up-down)and Z(anterior-posterior)axis during axial loading were recorded by dynamic capture instrument.Results The overall left-right,up-down and anterior-posterior displacement of the fibula ranged from 0.32 mm to 0.70 mm,-0.27 mm to-0.23 mm and 0.23 mm to 0.32 mm,and the maximum difference was 0.09 mm.The overall left-right,up-down and anterior-posterior displacement of medial malleolus fracture in the tibia range from 0.02 mm to 0.14 mm,-0.80 mm to-0.19 mm and-0.78 mm to-0.13 mm.The overall left-right,up-down and anterior-posterior displacement of lateral malleolus fracture in the tibia ranged from-0.07 mm to 0.05 mm,-0.36 mm to-0.03 mm,0.27 mm to 0.47 mm.Conclusions The horseshoe ring external fixator can not only stabilize the fracture end,but also produce micromotion which is beneficial to fracture healing,which accords with biomechanical characteristics of fracture healing.The external fixator structure is simple,suitable for the treatment of Pilon fracture,and worthy of popularization and application.
作者 陈洋 刘广伟 成永忠 黄晓宇 陈奕历 陈泓颖 汪雄伟 赵继阳 史长龙 CHEN Yang;LIU Guangwei;CHENG Yongzhong;HUANG Xiaoyu;CHEN Yili;CHEN Hongying;WANG Xiongwei;ZHAO Jiyang;SHI Changlong(No.1 Department of Traumatology,Wangjing Hospital,Chinese Academy of Chinese Medical Sciences,Beijing 100102,China;School of Clinical Medicine,Beijing University of Chinese Medicine,Beijing 100102,China;Beijing Key Laboratory of Bone Setting Technology of Traditional Chinese Medicine,Beijing 100102,China;Department of Traumatic Joint,the Third Affiliated Hospital of Beijing University of Chinese Medicine,Beijing 100102,China)
出处 《医用生物力学》 CAS CSCD 北大核心 2022年第3期498-503,共6页 Journal of Medical Biomechanics
基金 中国中医科学院科技创新工程项目(C12021A02008) 首都临床特色应用研究与成果推广(Z161100000516111) 2020年度北京中医药大学中央高校基本科研业务费研究生创新创业类自主选题(2020-jxs-022)。
关键词 PILON骨折 马蹄环 外固定架 Pilon fracture horseshoe ring external fixator
  • 相关文献

参考文献13

二级参考文献103

共引文献86

同被引文献43

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部