摘要
为得到轨道电路设备在不同温度、湿度环境下的雷电冲击传递特性规律,搭建不同温度、湿度环境条件下开展雷电冲击响应特性测试的试验平台,开展轨道电路关键设备在不同温度、湿度环境下的共模、差模雷电响应特性试验。研究试验获得在不同温度/湿度情况下的雷电冲击传递特性规律,为优化轨道电路设备雷电防护设计提供参考。试验结果表明:随着环境温度升高,设备共模和差模雷电冲击响应峰值均呈现上升趋势;随着环境湿度升高,设备差模雷电冲击响应峰值呈现下降趋势,设备共模雷电冲击过电压基本不受环境湿度影响。
In order to obtain the lightning impact characteristics of track circuit equipment under different temperature and humidity conditions,the tests of common mode and differential mode lightning response characteristics are carried out on its key equipment under different conditions.The test results show that the ambient temperature is positively correlated with the peak value of common mode and differential mode lightning responses,while the ambient humidity is negatively correlated with the peak value of differential mode lightning responses and is basically not affected by the common mode lightning impulse overvoltage of equipment.
作者
徐叶
高彬
李博
周雨秋
向念文
张威
Xu Ye;Gao Bin;Li Bo;Zhou Yuqiu;Xiang Nianwen;Zhang Wei(Beijing Railway Signal Co.,Ltd.,Beijing 102613,China;Hefei University of Technology,Hefei 230009,China;CRSC Research&Design Institute Group Co.,Ltd.,Beijing 100070,China)
出处
《铁路通信信号工程技术》
2022年第7期23-29,共7页
Railway Signalling & Communication Engineering
基金
国家自然科学基金项目(U1834204)
中国铁路通信信号股份有限公司重大科技专项(2018J02)。
关键词
高速铁路
共模雷电冲击
差模雷电冲击
雷电冲击响应
high-speed railway
common mode lightning impulse
diff erential mode lightning impulse
lightning impulse response