摘要
在使用10kV开关柜时,有一个比较常见的使用问题即内部电弧故障方面。需要在应用时10kV开关柜时强化主动型电弧故障保护作用,以此让开关柜更具安全使用效能。要提升电弧故障检测效能,获取熄弧单元检测时出现的弧光信号,选择行之有效的解决方案。本文重点探讨10kV开关柜中电弧故障的危害现象,基于此,阐释相应的解决方案。
When using 10kV switchgear,there is a common problem,that is,internal arc fault.It is necessary to strengthen the active arc fault protection in the application of 10kV switchgear,so as to make the switchgear more safe.To improve the efficiency of arc fault detection,obtain the arc signal during arc extinguishing unit detection,and select an effective solution.This paper focuses on the harmful phenomenon of arc fault in 10kV switchgear,and explains the corresponding solutions based on this.
作者
边志瑞
Bian Zhirui(Zhidan oil production plant of Yanchang Oilfield Co.,Ltd,Yan’an Shaanxi,717500)
出处
《电子测试》
2022年第13期126-128,共3页
Electronic Test