针对河钢唐钢冷轧薄板厂二镀锌机组焊机液压系统压力降低故障,从液位、温度、滤芯、溢流阀、液压泵和蓄能器各方面分析造成的原因,最终判断故障的原因是蓄能器内气囊破损,及时采取了解决措施,并总结、归纳出蓄能器维修要点。
The pressure of the hydraulic system of the secondary galvanizing unit welder was decreased in Hesteel Tanggang Cold Rolling Sheet Mill.Aiming at this fault,the reason is analyzed from the aspects of liquid level,temperature,filter,overflow valve,hydraulic pump and accumulator.It is confirmed that the reason is inner airbag broken.The countermeasures are taken The key points of maintenance are concluded and summarized.
作者
曹堃
CAO Kun(Cold Rolling Sheet Mill of Tangshan Iron&Steel Group Co.,Ltd,Tangshan 063016)
出处
《冶金设备管理与维修》
2022年第3期10-12,共3页
Metallurgical Equipment Management and Maintenance
关键词
蓄能器
压力降低
液压系统
镀锌机组
Accumulator
pressure
decrease
hydraulic system
galvanizing unit