期刊文献+

调速器油泵频繁启动分析及处理方案 被引量:1

Analysis on Frequent Start-up of Governor Oil Pump and Treatment Scheme
下载PDF
导出
摘要 调速器是水电厂中重要设备,调速器油泵的频繁启动给电厂安全生产带来了一定压力。通过对调速器油泵频繁启动的原因进行分析,总结提出了相应的处理方法:调整主配零位;加强油质过滤净化;及时更换接力器密封;设置合理油气比例;设置合理的副环参数等等,成功应用于阿海水电站运维,保障机组的安全稳定运行。 Governor is an important equipment in hydropower plant.Frequent start-up of oil pump of governor brings pressure to safety in production of power plant.Through the analysis of reasons for frequent start-up of governor oil pump,this paper summarizes and proposes corresponding treatment methods.It includes adjusting main matching zero position,strengthening oil filtering and purifying,replacing relay seal in time,setting reasonable oil-gas ratio and setting reasonable secondary ring parameters.It is successfully applied in operation and maintenance of Ahai Hydropower Station to ensure safe and stable operation of the unit.
作者 徐有为 XU You-wei(Yunnan Huadian Jinsha River Midstream Hydropower Development Co.,Ltd.,Ahai Power Generation Branch,Lijiang 674100,China)
出处 《云南水力发电》 2022年第S01期38-39,65,共3页 Yunnan Water Power
关键词 调速器 油泵 频繁启动 原因分析 governor oil pump frequent start-up cause analysis