摘要
探讨位于公共绿地的能源中心,选用冷水机组+风冷热泵+水蓄冷作为冷源,电锅炉+水蓄热作为热源。考虑到冷却塔和风冷热泵机组放在地面会影响景观,结合能源中心的进排风系统,设计了采用全地下布置方案,即将冷却塔和风冷热泵机组放入地下一层,探讨了地下建筑中冷却塔和风冷热泵的布置形式。
The energy center is located in the public green space, with chiller & air-cooled heat pump&water storage as the cold source and electric boiler & water storage as the heat source. Considering that placing the cooling tower and air-cooled heat pump unit on the ground will damage the landscape,combined with the air inlet and exhaust system of the energy center, a set of underground layout scheme is designed, that is, the cooling tower and air-cooled heat pump unit are placed on the ground floor, and the layout forms of cooling tower and air-cooled heat pump in underground buildings are discussed.
作者
潘俊
徐腾飞
殷仁豪
刘轶鹏
白涛
PAN Jun;XU Tengfei;YIN Renhao;Liu YiPeng;BAI Tao(Shanghai Electric Power Design Institute Co.,Ltd.;State Grid Shanghai Integrated Energy Service Co.,Ltd.)
出处
《上海节能》
2022年第6期738-743,共6页
Shanghai Energy Saving
关键词
能源中心
全地下布置
运行策略
节能技术
Energy Center
Full Underground Layout
Operation policy
Energy Saving Technology