随着我国城市化进程的不断加快,大型公共建筑不断出现.屋面虹吸雨水系统以其高效的排水能力.在大型公共建筑中得到了广泛运用。结合敞开式停车楼屋面的特点.探讨了雨水系统、暴雨重现期等设计参数的选取,并对存在的问题进行分析,为大型公共建筑雨水系统设计安全性和可靠性提供技术参考。
With the acceleration of urbanization in China,large public buildings appear constantly.Roof siphon rainwater drainage system is widely used in large public buildings because of its efficient drainage capacity.According to the characteristics of open parking roof,this article discusses the selection of design parameters such as rainwater system selection and rainstorm recurrence period,and analyzes the common problems,which provides technical reference for the design safety and reliability of rainwater system in large public buildings.
作者
周旭辉
李伟
于妮琼
ZHOU Xuhui;LI Wei;YU Niqiong(China Architecture Northwest Design and Research Insitute Co.,Ltd.,Xi'an 710018,China)
出处
《给水排水》
CSCD
北大核心
2022年第5期111-114,共4页
Water & Wastewater Engineering
关键词
大型屋面
虹吸雨水系统
敞开式停车楼
汇水面积
重现期
Large roof
Siphon rainwater system
Open parking building
Catchment area
Recurrence period