摘要 目的探讨自适应蒙特卡洛法(aMCM)用于确认自上而下方法评定测量不确定度(简称不确定度)的可行性。方法用aMCM确认临床实验室基于自上而下方法评定不确定度的效果,若aMCM与自上而下方法评定结果的绝对差值低于规定的数值容差,则确认通过;利用MatLab软件编制aMCM确认程序。结果aMCM与自上而下方法评定结果的绝对差值低于规定的数值容差,自上而下评定不确定度的方法通过了aMCM的确认。结论建立的aMCM可用于自上而下不确定度评定结果的确认。 Objective To investigate the feasibility of adaptive Monte Carlo method(aMCM)for top-down uncertainty assessment.Methods In case of uncertainty assessment based on top-down assessment in clinical laboratories,aMCM was used for verification.If the absolute difference between aMCM and top-down assessment results was less than the specified numerical tolerance,the verification was passed.The aMCM verification program was developed by MatLab software.Results The absolute difference between the results evaluated by aMCM and the top-down assessment was less than the specified numerical tolerance,and the top-down assessment was verified by aMCM.Conclusions The established aMCM can be used to verify the uncertainty evaluation results of the top-down assessment.
作者 王志方 李亚博 梁曼 安舒琪 韩艳林 WANG Zhifang;LI Yabo;LIANG Man;AN Shuqi;HAN Yanlin(Reference Laboratory,Autobio Diagnostics Co.,Ltd.,Zhengzhou 450016,Henan,China)
出处 《检验医学》 CAS 2022年第4期382-386,共5页 Laboratory Medicine
关键词 蒙特卡洛法 自适应蒙特卡洛法 自上而下方法 测量不确定度 Monte Carlo method Adaptive Monte Carlo method Top-down Measurement uncertainty
  • 相关文献

参考文献4

二级参考文献21

  • 1LIU Zhi-quan ZHANG Ying-hua LI Guang-he ZHANG Xu.Sensitivity of key factors and uncertainties in health risk assessment of benzene pollutant[J].Journal of Environmental Sciences,2007,19(10):1272-1280. 被引量:8
  • 2ISO 18153. In vitro diagnostic medical devices-Measurement of quantities in biological samples-Metrological traceability of values for catalytic concentration of enzymes assigned to calibrators and control materials [S]. /SO,2003. 被引量:1
  • 3Infusino I, Schumann G, Ceriotti F,et al. Standardization in clinical enzymology: a challenge for the theory of metrologieal traceability [J]. Clin Chem Lab Med,2010,48(3) :301-307. 被引量:1
  • 4ISO/IEC Guide 98-3. Uncertainty of measurement-Part3: Guide to the expRession of uncertainty in measurement ( GUM: 1995 ) [ S ]. ISO/IEC ,2008. 被引量:1
  • 5JCGM 101. Evaluation of measurement data Supplement 1 to the "Guide to the expRession of uncertainty in measurement" -- Propa-gation of distributions using a Monte Carlo method [ M ]. JCGM ,2008. 被引量:1
  • 6Schumann G, Bonora R, Ceriotti F, et al. IFCC Primary Reference ProceduRes for the Measurement of Catalytic Activity Concentrations of Enzymes at 37 C. Part 2. Reference Procedure for the Measure- ment of Catalytic Activity Concentration of Creatine Kinase [ ATP: Creatine N-Phosphotransferase ( CK), EC 2.7. 3.2 1 [ J ]. Clin Chem Lab Med,2002,40(6) :635-642. 被引量:1
  • 7中国合格评定国家认可委员会.CNAS-CL33:检测和校准实验室能力认可准则在临床酶学参考测量领域的应用说明[Z].2011-09-22. 被引量:1
  • 8EURACHEM/CITAC Guide, Quantifying Uncertainty in Analytical Measurement[ M]. 3rd ed. London :Laboratory of the Government Chemist, 2012 : 108-111. 被引量:1
  • 9黄美发,景晖,匡兵,钟艳如,蒋向前.基于拟蒙特卡罗方法的测量不确定度评定[J].仪器仪表学报,2009,30(1):120-125. 被引量:36
  • 10宋明顺,王伟.Monte Carlo方法评定测量不确定度中模拟样本数M的确定[J].计量学报,2010(1):91-96. 被引量:12

共引文献7

同被引文献20

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部