摘要 铁路长大隧道的无线覆盖以基站拉远直放站的方式为主,但是直放站并不能无限制地拉远。同时,针对超长隧道场景,设置单套远端机时,1.5 km的间距不一定满足重叠区的要求。基于直放站的两种组网方式,针对GSM和直放站的特性以及漏缆和光缆的传播特性,通过公式推导给出远端机的理想拉远距离。结合链路预算,分析超长隧道直放站的单点故障下的解决方案,给出通用的切换区设备间距的建议。 The wireless coverage of long railway tunnels is mainly by the way of extending the distance of repeater from the base station,however,the distance cannot be extended without limitation.At the same time,for the long railway tunnel scenario,when a single set of remote terminal is set up,the spacing of 1.5 km does not necessarily meet the requirements of the design specifications for overlapping area.In this paper,based on the two networking modes of repeater,aiming at the characteristics of GSM and the repeater as well as the propagation characteristics of leaky cables and optical cables,the ideal extended distance of the remote terminal is given through formula derivation.Based on the link budget analysis of the single-point fault solution of the repeater in the long railway tunnel,the general spacing between devices in the switching zone is proposed.