期刊文献+

德士古水煤浆加压气化装置真空闪蒸系统存在的问题及处理措施 被引量:2

Problems and Treatment Measures of Vacuum Flash System in Texaco Coal-Water Slurry Pressurized Gasification Unit
下载PDF
导出
摘要 德士古水煤浆加压气化装置生产负荷提高后,气化炉及碳洗塔黑水排放量增大,灰水处理单元的真空闪蒸系统出现超压、超温现象。通过对真空闪蒸冷凝器进行机械清洗、增大循环冷却水流量、调整真空闪蒸系统的工艺流程,有效解决了黑水排放负荷增大后对真空闪蒸系统的影响,实现了装置的长周期稳定运行。 After the production load of Texaco coal-water slurry pressurized gasification unit increases,the black water discharge of gasifier and carbon scrubber increases,the vacuum flash system of ash water treatment unit shows overpressure and overheated.By mechanically cleaning the vacuum flash condenser,increasing the flow of circulating cooling water and adjusting the process flow of vacuum flash system,the influence of increasing black water discharge load on vacuum flash system is effectively solved,and stable long-term operation of the unit is realized.
作者 张春练 娄奥林 易昌国 石国弘 吴吉 ZHANG Chunlian;LOU Aolin;YI Changguo;SHI Guohong;WU Ji(Guizhou Chitianhua Tongzi Chemical Industry Co.,Ltd.,Tongzi,Guizhou 563200,China)
出处 《肥料与健康》 CAS 2022年第2期61-63,共3页 Fertilizer & Health
关键词 德士古水煤浆加压气化 真空闪蒸 灰水处理 冷凝器 Texaco coal-water slurry pressurized gasification vacuum flash ash water treatment condenser
  • 相关文献

参考文献1

共引文献4

同被引文献11

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;