期刊文献+

基于双向测量的转子真实不平衡响应分析技术

Analysis technology of real unbalanced response of rotor based on bidirectional measurement
下载PDF
导出
摘要 针对航空发动机等复杂转子机械,部分转子系统中基频振动往往不只受到不平衡一种因素的影响,还可能受到同频干扰振动的影响,导致实际测量的转子基频振动不能准确反映转子不平衡量的问题,通过地面转子实验台试验及理论分析等方式,探究了同频干扰振动对转子不平衡测量结果的影响,建立了一种基于双向测量的转子真实不平衡响应分析技术。利用不同配重构型试验中同截面不同方向的振动测量数据,分析出转子系统的真实不平衡响应。研究结果表明,利用此技术得出的真实不平衡振动可稳定在10.84%以内,提高了现场动平衡效率。 For aero-engine and other complex rotor machinery,the fundamental frequency vibration in some rotor systems is often affected not only by one factor of imbalance,but also by interference vibration at the same frequency.As a result,the actual measured fundamental frequency vibration of the rotor cannot ac⁃curately reflect the amount of rotor imbalance.The effects of the same frequency interference vibration on the rotor unbalance measurement results by tests of ground rotor and theoretical analysis was presented,and a true rotor unbalance response analysis technology based on two-way measurement was established,which can be reconstructed using different configurations.The real unbalanced response of the rotor system was analyzed by vibration measurement data of the same section and in different directions.The results of multi⁃ple tests show that the real unbalanced vibration analyzed by this method can be stable within 10.84%,which increases the field dynamic balance effectiveness.
作者 解梦涛 张霞妹 张强波 XIE Meng-tao;ZHANG Xia-mei;ZHANG Qiang-bo(Power-Plant Institute,Chinese Flight Test Establishment,Xi’an 710089,China)
出处 《燃气涡轮试验与研究》 2021年第5期28-32,共5页 Gas Turbine Experiment and Research
关键词 航空发动机 转子机械 现场动平衡 基频振动 不平衡响应 同频干扰振动 配平 双向测量 areo-engine rotor machinery field dynamic balance fundamental frequency vibration unbalanced response same frequency interference vibration trim two-way measurement
  • 相关文献

参考文献12

二级参考文献36

共引文献94

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部