摘要 阐述660MW超超临界机组,1瓦轴振偏大发生率较高,原因复杂、处理措施比较典型的特点,探讨华电江苏望亭发电厂某机组1瓦振动偏大的问题,分析原因和处理措施,包括动静碰磨、负载分配不均和盘车中心对1瓦轴振大的影响。 This paper expounds the characteristics of 660 MW ultra supercritical unit, such as high occurrence rate of 1-bearing shaft vibration, complex causes and typical treatment measures, discusses the problem of 1-bearing shaft vibration of a unit in Jiangsu Wangting power plant of Huadian, analyzes the causes and treatment measures, including the impact of dynamic and static friction, uneven load distribution and turning center on 1-bearing shaft vibration.
作者 金纬 JIN Wei(Jiangsu Wangting Power Generation Branch of China Huadian Group Co.,Ltd.,Jiangsu 215155,China.)
出处 《集成电路应用》 2022年第3期292-293,共2页 Application of IC
关键词 超超临界机组 1瓦轴振偏 负载分配 660MW ultra supercritical unit 1-bearing shaft vibration deviation load distribution 660MW