城市地下综合管廊,是一种相对密闭的地下构筑物。廊体内很容易沉积大量的热空气和有害气体,发生火灾事故的概率较高。一旦发生火灾事故,其产生的危害与损失也难以估量。根据我国相关法律法规,城市地下综合管廊必须要进行防火分区的设计。文章重点针对城市地下综合管廊的防火分区设计进行详细的分析,旨在提升城市地下综合管廊运营的安全性与稳定性,以供参考。
Urban underground comprehensive pipe gallery is a relatively closed underground structure. It is easy to deposit a large amount of hot air and harmful gases in the corridor, and the probability of fire accidents is high. Once a fire accident occurs, the harm and loss it produces are also incalculable. According to relevant laws and regulations of our country,urban underground comprehensive pipe gallery must be designed with fire compartment. The paper focuses on the detailed analysis of the fire compartment design of the urban underground comprehensive pipe gallery,aiming to improve the safety and stability of the operation of the urban underground comprehensive pipe gallery for reference.
作者
於陈磊
Yu Chenlei(Dongqianhu Fire and Rescue Section of Ningbo Municipal,Zhejiang Ningbo 315000)
关键词
城市
地下
综合管廊
防火分区
设计
urban
underground
comprehensive pipe gallery
fire compartment
design