期刊文献+

双能量CT物质分离技术在椎体骨髓水肿中的应用 被引量:1

Application of dual-energy CT material separation technology in vertebral BME
下载PDF
导出
摘要 双能量CT通过两种物质的不同X线衰减特征表达一种物质的X线衰减特征,经过后处理软件生成反映某种物质X线衰减特征的彩色融合图,从而达到物质分离的作用。常规CT只能反映脊柱形态学改变,双能量CT物质分离技术可以实现脊柱骨髓水肿的功能成像和多参数成像。本文概述双能量CT物质分离技术中不同基物质对在椎体骨髓水肿中的应用进展。 Dual-energy CT expresses the X-ray attenuation characteristics of a substance through the different X-ray attenuation characteristics of two substances,and the color fusion image reflecting the X-ray attenuation characteristics of a substance is generated by post-processing software,so as to achieve the separation of substances.Conventional CT can only reflect the morphological changes of the spine.Dual-energy CT material separation technique can achieve functional imaging and multi-parameter imaging of spinal lesions.This paper reviews the progress in the application of multiple base substance pairs in dual-energy CT material separation in spinal lesions.
作者 陈盛 朱新进 李康倩 CHEN Sheng;ZHU Xinjin;Li KANG Qian(Guangdong Medical University,Zhanjiang,Guangdong 524001,China;The Second People's Hospital of Foshan,Foshan,Guangdong 528000,China)
出处 《影像研究与医学应用》 2022年第4期1-3,共3页 Journal of Imaging Research and Medical Applications
关键词 双能量CT 脊柱 物质分离技术 骨髓水肿 Dual energy CT Spine Substance separation technique Bone marrow edema
  • 相关文献

参考文献5

二级参考文献37

  • 1Matsumoto K, Jinzaki M, Tanami Y, et al. Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology,2011,259:257-262. 被引量:1
  • 2Yamada Y, Jinzaki M, Tanami Y, et al. Virtual monochromatic spectral imaging for the evaluation of hypovascular hepatic metastases-the optimal monochromatic level with fast kilovoltage switching dual-energy computed tomography. Invest Radiol,2012,47:292-298. 被引量:1
  • 3Lin XZ, Miao F, Li JY, et al. High-definition CT gemstone spectral imaging of the brain: initial results of selecting optimal monochromatic image for beam-hardening artifacts and image noise reduction.J Comput Assist Tomogr, 2011,35:294-297. 被引量:1
  • 4Lu PJ, Lin XZ, Chen KM, et al. Spectral CT in patients with small HCC: investigation of image quality and diagnostic accuracy. Eur Radiol, 2012, 22:2117-2124. 被引量:1
  • 5Wu HW, Cheng JJ, Li JY, et al. Pulmonary embolism detection and characterization through quantitative iodine-based material decomposition images with spectral computed tomography imaging. Investigative Radiology,2012,47:85-91. 被引量:1
  • 6Lin XZ, Wu ZW, Tao R, et al. Dual energy spectral CT imaging of insulinoma---value in preoperative diagnosis compared with conventional multidetector CT. E JR,2012,81:2487-2494. 被引量:1
  • 7Kaza RK, Caoili EM, Cohan RH, et al. Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual-energy CT. A JR,2011,197:1375-1381. 被引量:1
  • 8Li M, Zheng X, Li J, et al. Dual-energy computed tomography imaging of thyroid nodule specimens: comparison with pathologic findings. Invest Radiol, 2012, 47:58-64. 被引量:1
  • 9Yuan R, Shuman WP, Earls JP, et al. Reduced iodine load at CT pulmonary angiography with dual-energy monochromatic imaging: comparison with standard CT pulmonary angiography--A prospective randomized trial. Radiology, 2012, 262:290-297. 被引量:1
  • 10Heye T, Nelson RC, Ho LM, et al. Dual-energy CT applications in the abdomen.A JR, 2012,199:s64-s70. 被引量:1

共引文献355

同被引文献11

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部