目的观察放射治疗(放疗)辅助固定装置用于^(99)Tc^(m)-TcO_(4)^(-)/^(99)Tc^(m)-MIBI甲状旁腺减影法显像的价值。方法将33例甲状旁腺功能亢进症(HPT)患者随机分组为辅助组(n=17)和常规组(n=16),分别以放疗辅助固定装置和常规头部托架加以固定,行^(99)Tc^(m)-TcO_(4)^(-)/^(99)Tc^(m)-MIBI SPECT显像;对2组减影处理中的图像位置调整幅度(AMS)进行分级,并比较组间差异。结果减影处理过程中,辅助组AMS分级0级6例、Ⅰ级7例、Ⅱ级4例、Ⅲ级0例,常规组0级2例、Ⅰ级4例、Ⅱ级6例、Ⅲ级4例,组间AMS分级差异具有统计学意义(P<0.01)。结论放射治疗辅助固定装置用于甲状旁腺SPECT显像可降低患者移动幅度,有利于改进图像质量和提高定位准确度。
Objective To observe the value of radiotherapy-assistance posture fixing device for ^(99)Tc^(m)-TcO_(4)^(-) and ^(99)Tc^(m)-MIBI parathyroid scintigraphy of subtraction imaging.Methods Totally 33 patients with hyperparathyroidism(HPT)were randomly divided into auxiliary group(n=17)and routine group(n=16).The patients were fixed with radiotherapy-assistance posture fixing device(auxiliary group)or conventional head bracket device(routine group),respectively,and ^(99)Tc^(m)-TcO_(4)^(-)/^(99)Tc^(m)-MIBI SPECT imaging was performed.The image amplitude of motion shift(AMS)during subtraction processing were graded and compared between groups.Results AMS during subtraction in auxiliary group were grade 0 in 6 cases,gradeⅠin 7 cases,gradeⅡin 4 cases,and no gradeⅢwas found.In routine group,AMS during subtraction were grade 0 in 2 cases,gradeⅠin 4 cases,gradeⅡin 6 cases and gradeⅢin 4 cases.There was significant difference of AMS between groups(P<0.01).Conclusion Radiotherapy-assistance posture fixing device was valuable for parathyroid SPECT imaging,which could reduce patients body motion and increase imaging quality and the accuracy of localization.
作者
孙志勇
程莹
咸婧
薛刚
周帅
黄叶
周后蓉
王庆旭
SUN Zhiyong;CHENG Ying;XIAN Jing;XUE Gang;ZHOU Shuai;HUANG Ye;ZHOU Hourong;WANG Qingxu(Department of Nuclear Medicine,the General Hospital of Western Theater Command,PLA,Chengdu 610083,China;Department of Endocrinology,the General Hospital of Western Theater Command,PLA,Chengdu 610083,China;Department of Radiotherapy,the General Hospital of Western Theater Command,PLA,Chengdu 610083,China;Department of Breast and Thyroid Surgery,the General Hospital of Western Theater Command,PLA,Chengdu 610083,China)
出处
《中国医学影像技术》
CSCD
北大核心
2022年第2期291-294,共4页
Chinese Journal of Medical Imaging Technology