摘要
本文以硫化氢气体报警器计量校准为例,通过具体实验对硫化氢气体报警器计量校准开展示值误差测量不确定度的评定,阐述了评定的方法和过程,得出不确定评定结果及测量结果的报告,为类似的技术工作提供参考。
Taking the calibration of hydrogen sulfide gas alarm as an example,this paper evaluates the uncertainty of indication error measurement of hydrogen sulfide gas alarm calibration through concrete experiments,and expounds the method and process of the evaluation,the report of uncertain evaluation result and measurement result can provide reference for similar technical work.
作者
谢延斌
樊艳霞
XIE Yan-bin;FAN Yan-xia(Karamay City Quality and Metrology Inspection Institute,Karamay 834000,China)
关键词
示值误差
测量不确定度
测量模型
测量重复性
仪器分辨力
indication error
measurement uncertainty
measurement model
measurement repeatability
instrument resolution