期刊文献+

高压隔离开关故障分析及对策 被引量:1

Fault Analysis and Solution of High Voltage Disconnector
下载PDF
导出
摘要 介绍电力机车新型高压隔离开关的结构和工作原理,以及高压隔离开关的控制逻辑。对发生带载分断故障进行还原和原因分析,并提出相应的对策。优化后,高压隔离开关稳定运行半年以上,实践证明解决措施有效。 This paper introduces the structure and working principle of the new high voltage disconnector for electric locomotive, and the control logic. Restore and analyze the causes of on load breaking fault, and put forward corresponding countermeasures. After optimization, the high voltage disconnector has operated stably for more than half a year, and the practice has proved that the solutions are effective.
作者 邹异民 陈哲 恒放 李涛 曾凡军 Zou Yimin;Chen Zhe;Heng Fang;Li Tao;Zeng Fanjun(Product R&D center of CRRC Zhuzhou Locomotive Co.,Ltd,Zhuzhou,Zhuzhou 412001,China;The State Key Laboratory of Heavy Duty AC Drive Electric Locomotive Systems Integration\The State Key Laboratory of Traction Power,Zhuzhou 412001,China;Electrical Equipment Branch of CRRC Zhuzhou Locomotive Co.,Ltd,Zhuzhou 412001,China)
出处 《科学技术创新》 2022年第2期49-52,共4页 Scientific and Technological Innovation
关键词 电力机车 高压隔离开关 电磁阀 故障 解决措施 Electric locomotive High voltage disconnector Solenoid valve Fault Solution