摘要 目的:比较罗氏6500和美国IRIS IQ200尿沉渣分析仪对于尿液结晶的检测效能。方法:抽取广州医科大学附属第六医院2020年6月至2020年7月的就诊人员尿液样本100份作为研究对象,均行罗氏6500尿沉渣分析仪检测与美国IRIS IQ200尿沉渣分析仪检测,以人工显微镜检查结果为金标准,比较两种检测方法的检测效能。结果:美国IRIS IQ200尿沉渣分析仪检查的灵敏度为88.57 %,特异度是92.31 %,与罗氏6500尿沉渣分析仪的检查结果比较(灵敏度是94.29 %,特异度是90.77 %),差异均无统计学意义(P>0.05)。结论:罗氏6500和美国IRIS IQ200尿沉渣分析仪对于尿液结晶的检测效能相似,但两者原理不同,可根据临床检验需要选择更为适用的检验系统。 Objective To analyze the determination efficiency of Roche 6500 and IRIS IQ200 urine sediment analyzer for urine crystallization.Methods A total of 100 urine samples were collected from the Sixth Affiliated Hospital of Guangzhou Medical University from June 2020 to July 2020.All samples were tested by Roche 6500 urine sediment analyzer and IRIS IQ200 urine sediment analyzer.The results of manual microscopy were taken as the gold standard to compare the detection efficiency of the two detection methods.Results The sensitivity and specificity of the American IRIS IQ200 urine sediment analyzer were 88.57% and 92.31%,and there was no statistical significance (P > 0.05) compared with the results of the Roche 6500 urine sediment analyzer (94.29% and 90.77%).Conclusion Roche 6500 and IRIS IQ200 urine sediment analyzer have similar detection efficiency for urine crystallization,but their principles are different.Therefore,a more suitable test system can be selected according to the needs of clinical testing.
作者 朱杏谊 梁大立 王安 唐晓薇 ZHU Xing-yi;LIANG Da-li;WANG An;TANG Xiao-wei(The Sixth Affiliated Hospital of Guangzhou Medical University,Qingyuan People's Hospital,Guangdong Qingyuan 511518)
出处 《深圳中西医结合杂志》 2021年第20期89-91,共3页 Shenzhen Journal of Integrated Traditional Chinese and Western Medicine
关键词 尿液结晶 尿液分析 全自动尿沉渣分析仪 显微镜检查 Urine crystallization Urinalysis Automatic urine sediment analyzer Microscopic examination
  • 相关文献

参考文献10

二级参考文献53

共引文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部