期刊文献+

低温环境对变压器油中溶解气体在线监测装置的影响分析 被引量:3

Influence analysis of low temperature on on-line monitoring device for dissolved gas in transformer oil
下载PDF
导出
摘要 为解决变压器油中溶解气体在线监测装置在低温环境长期运行时存在的误报率高、故障频发、维护工作繁重等问题,开展变压器油中溶解气体在线监测装置在低温条件下长期运行的常见故障分析,总结低温环境对监测装置的电子器件、材料等方面的影响,提出低温条件下变压器油中溶解气体在线监测装置的改进建议。 In order to solve the problems of high false alarm rate,frequent faults and heavy maintenance of on-line monitoring device for dissolved gas in transformer oil during long-term operation in low-temperature environment,carry out common fault analysis of on-line monitoring device for dissolved gas in transformer oil under low-temperature conditions,and summarize the impact of low-temperature environment on electronic devices and materials of monitoring device.The improvement suggestions of on-line monitoring device for dissolved gas in transformer oil at low temperature are put forward.
作者 杨力 赵婧 张德文 孙海明 张朋 梁建权 YANG Li;ZHAO Jing;ZHANG Dewen;SUN Haiming;ZHANG Peng;LIANG Jianquan(State Grid Heilongjiang Electric Power Co.,Ltd.Electric Power Research Institute,Harbin 150030,China;State Grid Heilongjiang Electric Power Co.,Ltd.Yichun power supply company,Yichun 153000,China)
出处 《黑龙江电力》 CAS 2021年第6期530-532,共3页 Heilongjiang Electric Power
关键词 低温 变压器 故障分析 low temperature transformer fault analysis