期刊文献+

离心萃取机充氮测氧系统的设计与应用

Design and Application of Nitrogen Filling and Oxygen Measuring System for Centrifugal Extractor
下载PDF
导出
摘要 针对离心萃取机处理正辛烷、甲基叔丁基醚及乙酸叔丁酯等易燃、易爆、有毒物质出现的安全问题,设计一整套离心萃取机充氮测氧系统,对设备进行充氮保护并实时检测设备内氧含量,保证设备的安全稳定运行。解决了氮气进气引起的压力波动导致设备内气液平衡被破坏的问题,确定了离心萃取机压力波动范围,并进行模拟验证;设计充氮测氧系统全自动控制系统与控制逻辑,实现氧含量与压力值的自动调节。 Considering the safety matters of the centrifugal extractor in processing inflammable and explosive and toxic materials like normal octane,MTBE and tert-butyl acetate,a set of nitrogen-filling and oxygen-measuring system for the centrifugal extractor was designed to protect the equipment with nitrogen and to detect the oxygen content there in real time to ensure a safe and stable operation of the equipment so that the gas-liquid unbalance in the equipment caused by the pressure fluctuation that the nitrogen gas inlet incurred can be resolved and the pressure fluctuation range of the centrifugal extractor can be determined,including the simulation of it and designing both nitrogen-filling control system and control logic to realize auto-regulation of both oxygen content and pressure value.
作者 丁建国 陈崔龙 刘呈启 DING Jian-guo;CHEN Cui-long;LIU Cheng-qi(Hefei General Machinery Research Institute Co.,Ltd.;Hefei General Environment Control Technology Co.,Ltd.)
出处 《化工机械》 CAS 2021年第6期923-928,共6页 Chemical Engineering & Machinery
基金 国机集团2017年度重大科技专项计划项目(国机科〔2017〕456号) 合肥通用机械研究院青年科技基金项目(2019010378)。
关键词 离心萃取机 充氮测氧系统 溶剂萃取 离心分离 设计 centrifugal extractor nitrogen-filling and oxygen-measuring system solvent extraction centrifugal separation design