期刊文献+

空气悬架导向臂疲劳断裂失效分析

Analysis about Fatigue Fracture Failure of the Air Suspension Guide Arm
下载PDF
导出
摘要 某空气悬架导向臂经过70万次台架疲劳试验后发生了断裂。本文采用扫描电子显微镜、光谱仪、金相显微镜、洛氏硬度计等设备,对导向臂疲劳试验过程中的断裂原因进行了分析。结果表明导向臂的断裂失效属于疲劳断裂,断裂的主要原因是导向臂存在淬火开裂缺陷,该缺陷作为疲劳试验过程中的裂纹源,加速了疲劳断裂过程。 An air suspension guide arm was broken after 700,000 bench fatigue tests.By means of scanning electron microscope,spectrometer,metallographic microscope,Rockwell hardness tester and other equipments,the guide arm fracture reason in the process of fatigue test was analyzed.The results showed that the fracture failure of the guide arm was fatigue fracture,the main reason of fracture was the quenching crack defect of guide arm,as the crack source,the quenching crack accelerated the fatigue fracture process.
作者 李曜 姚铁华 许海龙 曹锋 Li Yao;Yao Tiehua;Xu Hailong;Cao feng(Jiangyin Xingcheng Special Steel Works CO.,Ltd.,Jiangyin 214400)
出处 《特钢技术》 CAS 2021年第3期46-48,共3页 Special Steel Technology
关键词 空气悬架导向臂 疲劳断裂 失效分析 air suspension guide arm fatigue fracture failure analysis